Skip to content
NOGTechnologien UG
DE EN
Start a project
SEC Security · architecture

Zones, not
luck.

We split production networks into zones and define every crossing explicitly. An infected office PC cannot reach a controller, and remote maintenance only runs through a controlled access point.

FrameworkIEC 62443-3-2 / 3-3
ModelPurdue (ISA-95)
Monitoringpassive, read-only
A1 Purdue model

Six levels, clearly separated.

Click a building block on the right. The diagram shows where it sits in the architecture.

LEVEL 4–5Enterprise ITERPMail / ADCloudLEVEL 3.5Industrial DMZJump-HostHistorianPatch serverLEVEL 3OperationsMESNOG SensorEngineeringLEVEL 2SupervisorySCADAHMIEdge-GWLEVEL 1Basic controlPLCDrivesSafety-SPS LEVEL 0Process · sensors · actuators FW 1FW 2FW 3 ✕ BLOCKED
A2 Attack path

Where segmentation stops an attack.

A typical sequence seen in many incidents. Keep scrolling: without separation the attack runs through, with a zone model it ends at the firewall.

Step 1

Phishing email

An employee opens a booby-trapped attachment in the office network.

Step 2

Office PC compromised

The attacker harvests credentials and looks for ways into the plant.

Step 3

IT/OT firewall

Default deny: there is no permitted connection from the office to the control level. Our sensor reports the attempt.

Step 4

SCADA / HMI

Without segmentation the HMI would be directly reachable.

Step 5

PLC manipulated

Without segmentation: setpoints change, the line stops.

A3 Frameworks

Standards are our toolkit.

For many companies NIS2 and the Cyber Resilience Act are now mandatory. We align architecture, tools and documentation with them so that audits become routine.

STD Industrial security
IEC 62443

Zones, conduits and security levels for automation systems. For asset owners, integrators and vendors.

STD ISMS
ISO/IEC 27001

Information security management system. We deliver the technical controls and evidence.

STD Germany
BSI IT-Grundschutz

The IND.1 and IND.2 modules for operational technology form the basis of our checklists.

STD EU directive
NIS2

Risk management, reporting duties and supply chain. Part of the German BSI Act since December 2025.

STD Products
Cyber Resilience Act

Reporting duties for manufacturers since 11 September 2026, full application from December 2027.

STD Data protection
GDPR

Data-minimising architecture, processing in Germany and clear deletion rules for log data.

NOG Contact · free first call

Let’s talk
about your
plant.

Tell us briefly what you are planning. We get back to you within two working days, on site if you prefer.

Start a project